Sstarter,ADX0017B,3phase,17A/7.5kw@414V,Incl contactor.  Sstarter,ADX0017B,3phase,17A/7.5kw@414V,Incl contactor.

ADX0017B - 3phase, 17Amp, 7.5kW@415v, 11kW@500V, Integrated bypass contactor, Aux supply 208 - 240Vac, +-10%, 50/60Hz Torque and current(350% -Normal duty/500% Heavy duty)/motor full load current) control. By overrating (up to 50% possible) the starter up to 700% of motor currents can be achieved. Time: Max starting=1000sec, Delay for each trip condition. Auto reset, Analog 0/2-10V or 0/4-20mA ramp or start/stop control. Digital display and membrane keypad. Hi/Low Voltage, Current,asymmetry,Power factor, motor torque, Power, motor thermal status, Heatsink temperature, Alarms conditions, Time stamped Alarm/event log(last 20) displayed. Real time clock, Maintenance(operating hours) alarm, Phase failure, Reversal, Frequency out of limits. SCR and by-pass contactor malfunction check. For very frequent staring the bypass contactor phase can be disabled. INPUTS: start + programmable stop + programmable analog/digital + 1 analog 0/2-10 or 0/4-20mA(by adding 500 ohm resistor). OUTPUTS: 3 programmable relays + 1 global alarm relay. Comms port:RS232(programming)/RS485(or remote keypad) port (Lovato/Modbus RTU) + modem (SMS/email) or PC. Multilanguage (Italian, English, french, Spanish)

 
 Lovato 
Sstarter,ADX0030B,3phase,30A/15kw@414V,Incl contactor.  Sstarter,ADX0030B,3phase,30A/15kw@414V,Incl contactor.

ADX0017B - 3phase, 30Amp, 15kW@415v, 18.5kW@500V, Integrated bypass contactor, Aux supply 208 - 240Vac, +-10%, 50/60Hz Torque and current(350% -Normal duty/500% Heavy duty)/motor full load current) control. By overrating (up to 50% possible) the starter up to 700% of motor currents can be achieved. Time: Max starting=1000sec, delay for each trip condition. Auto restart, Analog 0/2-10V or 0/4-20mA ramp or start/stop control. Digital display and membrane keypad. Hi/Low Voltage, Current,asymmetry,Power factor, motor torque, Power, motor thermal status, Heatsink temperature, Alarms conditions, Time stamped Alarm/event log(last 20) displayed. Real time clock, Maintenance(operating hours) alarm, Phase failure, Reversal, Frequency out of limits. SCR and by-pass contactor malfunction check. For very frequent staring the bypass contactor phase can be disabled. INPUTS: start + programmable stop + programmable analog/digital + 1 analog 0/2-10 or 0/4-20mA(by adding 500 ohm resistor). OUTPUTS: 3 programmable relays + 1 global alarm relay. Comms port:RS232(programming)/RS485(or remote keypad) port (Lovato/Modbus RTU) + modem (SMS/email) or PC. Multilanguage (Italian, English, french, Spanish)

 
 Lovato 
Sstarter,ADX0045B,3phase,45A/22kw@414V,Incl contactor.  Sstarter,ADX0045B,3phase,45A/22kw@414V,Incl contactor.

ADX0045B - 3phase, 45Amp, 22kW@415v, 30kW@500V, Integrated bypass contactor, Aux supply 208 - 240Vac, +-10%, 50/60Hz Torque and current(350% -Normal duty/500% Heavy duty)/motor full load current) control. By overrating (up to 50% possible) the starter up to 700% of motor currents can be achieved. Time: Max starting=1000sec, delay for each trip condition. Auto restart, Analog 0/2-10V or 0/4-20mA ramp or start/stop control. Digital display and membrane keypad. Hi/Low Voltage, Current,asymmetry,Power factor, motor torque, Power, motor thermal status, Heatsink temperature, Alarms conditions, Time stamped Alarm/event log(last 20) displayed. Real time clock, Maintenance(operating hours) alarm, Phase failure, Reversal, Frequency out of limits. SCR and by-pass contactor malfunction check. For very frequent staring the bypass contactor phase can be disabled. INPUTS: start + programmable stop + programmable analog/digital + 1 analog 0/2-10 or 0/4-20mA(by adding 500 ohm resistor). OUTPUTS: 3 programmable relays + 1 global alarm relay. Comms port:RS232(programming)/RS485(or remote keypad) port (Lovato/Modbus RTU) + modem (SMS/email) or PC. Multilanguage (Italian, English, french, Spanish)

 
 Lovato 
Sstarter,ADX0060B,3phase,60A/30kW@414V,Incl contactor.  Sstarter,ADX0060B,3phase,60A/30kW@414V,Incl contactor.

ADX0060B - 3phase, 60Amp, 30kW@415v, 37kW@500V, Integrated bypass contactor, Aux supply 208 - 240Vac, +-10%, 50/60Hz Torque and current(350% -Normal duty/500% Heavy duty)/motor full load current) control. By overrating (up to 50% possible) the starter up to 700% of motor currents can be achieved. Time: Max starting=1000sec, delay for each trip condition. Auto restart, Analog 0/2-10V or 0/4-20mA ramp or start/stop control. Digital display and membrane keypad. Hi/Low Voltage, Current,asymmetry,Power factor, motor torque, Power, motor thermal status, Heatsink temperature, Alarms conditions, Time stamped Alarm/event log(last 20) displayed. Real time clock, Maintenance(operating hours) alarm, Phase failure, Reversal, Frequency out of limits. SCR and by-pass contactor malfunction check. For very frequent staring the bypass contactor phase can be disabled. INPUTS: start + programmable stop + programmable analog/digital + 1 analog 0/2-10 or 0/4-20mA(by adding 500 ohm resistor). OUTPUTS: 3 programmable relays + 1 global alarm relay. Comms port:RS232(programming)/RS485(or remote keypad) port (Lovato/Modbus RTU) + modem (SMS/email) or PC. Multilanguage (Italian, English, french, Spanish)

 
 Lovato 
Sstarter,ADX0075B,3phase,75A/37kW@414V,Incl contactor.  Sstarter,ADX0075B,3phase,75A/37kW@414V,Incl contactor.

ADX0075B - 3phase, 75Amp, 37kW@415v, 45kW@500V, Integrated bypass contactor, Aux supply 208 - 240Vac, +-10%, 50/60Hz Torque and current(350% -Normal duty/500% Heavy duty)/motor full load current) control. By overrating (up to 50% possible) the starter up to 700% of motor currents can be achieved. Time: Max starting=1000sec, delay for each trip condition. Auto restart, Analog 0/2-10V or 0/4-20mA ramp or start/stop control. Digital display and membrane keypad. Hi/Low Voltage, Current,asymmetry,Power factor, motor torque, Power, motor thermal status, Heatsink temperature, Alarms conditions, Time stamped Alarm/event log(last 20) displayed. Real time clock, Maintenance(operating hours) alarm, Phase failure, Reversal, Frequency out of limits. SCR and by-pass contactor malfunction check. For very frequent staring the bypass contactor phase can be disabled. INPUTS: start + programmable stop + programmable analog/digital + 1 analog 0/2-10 or 0/4-20mA(by adding 500 ohm resistor). OUTPUTS: 3 programmable relays + 1 global alarm relay. Comms port:RS232(programming)/RS485(or remote keypad) port (Lovato/Modbus RTU) + modem (SMS/email) or PC. Multilanguage (Italian, English, french, Spanish)

 
 Lovato 
Sstarter,ADX0085B,3phase,85A/45kW@414V,Incl contactor.  Sstarter,ADX0085B,3phase,85A/45kW@414V,Incl contactor.

ADX0085B - 3phase, 85Amp, 45kW@415v, 55kW@500V, Integrated bypass contactor, Aux supply 208 - 240Vac, +-10%, 50/60Hz Torque and current(350% -Normal duty/500% Heavy duty)/motor full load current) control. By overrating (up to 50% possible) the starter up to 700% of motor currents can be achieved. Time: Max starting=1000sec, delay for each trip condition. Auto restart, Analog 0/2-10V or 0/4-20mA ramp or start/stop control. Digital display and membrane keypad. Hi/Low Voltage, Current,asymmetry,Power factor, motor torque, Power, motor thermal status, Heatsink temperature, Alarms conditions, Time stamped Alarm/event log(last 20) displayed. Real time clock, Maintenance(operating hours) alarm, Phase failure, Reversal, Frequency out of limits. SCR and by-pass contactor malfunction check. For very frequent staring the bypass contactor phase can be disabled. INPUTS: start + programmable stop + programmable analog/digital + 1 analog 0/2-10 or 0/4-20mA(by adding 500 ohm resistor). OUTPUTS: 3 programmable relays + 1 global alarm relay. Comms port:RS232(programming)/RS485(or remote keypad) port (Lovato/Modbus RTU) + modem (SMS/email) or PC. Multilanguage (Italian, English, french, Spanish)

 
 Lovato 
Sstarter,ADX0110B,3phase,110A/55kW@414V,Incl contactor.  Sstarter,ADX0110B,3phase,110A/55kW@414V,Incl contactor.

ADX0110B - 3phase, 110Amp, 55kW@415v, 75kW@500V, Integrated bypass contactor, Aux supply 208 - 240Vac, +-10%, 50/60Hz Torque and current(350% -Normal duty/500% Heavy duty)/motor full load current) control. By overrating (up to 50% possible) the starter up to 700% of motor currents can be achieved. Time: Max starting=1000sec, delay for each trip condition. Auto restart, Analog 0/2-10V or 0/4-20mA ramp or start/stop control. Digital display and membrane keypad. Hi/Low Voltage, Current,asymmetry,Power factor, motor torque, Power, motor thermal status, Heatsink temperature, Alarms conditions, Time stamped Alarm/event log(last 20) displayed. Real time clock, Maintenance(operating hours) alarm, Phase failure, Reversal, Frequency out of limits. SCR and by-pass contactor malfunction check. For very frequent staring the bypass contactor phase can be disabled. INPUTS: start + programmable stop + programmable analog/digital + 1 analog 0/2-10 or 0/4-20mA(by adding 500 ohm resistor). OUTPUTS: 3 programmable relays + 1 global alarm relay. Comms port:RS232(programming)/RS485(or remote keypad) port (Lovato/Modbus RTU) + modem (SMS/email) or PC. Multilanguage (Italian, English, french, Spanish)

 
 Lovato 
Sstarter,ADX0142B,3phase,142A/72kW@414V,Incl contactor.  Sstarter,ADX0142B,3phase,142A/72kW@414V,Incl contactor.

ADX0142B - 3phase, 142Amp, 75kW@415v, 90kW@500V, Integrated bypass contactor, Aux supply 208 - 240Vac, +-10%, 50/60Hz Torque and current(350% -Normal duty/500% Heavy duty)/motor full load current) control. By overrating (up to 50% possible) the starter up to 700% of motor currents can be achieved. Time: Max starting=1000sec, delay for each trip condition. Auto restart, Analog 0/2-10V or 0/4-20mA ramp or start/stop control. Digital display and membrane keypad. Hi/Low Voltage, Current,asymmetry,Power factor, motor torque, Power, motor thermal status, Heatsink temperature, Alarms conditions, Time stamped Alarm/event log(last 20) displayed. Real time clock, Maintenance(operating hours) alarm, Phase failure, Reversal, Frequency out of limits. SCR and by-pass contactor malfunction check. For very frequent staring the bypass contactor phase can be disabled. INPUTS: start + programmable stop + programmable analog/digital + 1 analog 0/2-10 or 0/4-20mA(by adding 500 ohm resistor). OUTPUTS: 3 programmable relays + 1 global alarm relay. Comms port:RS232(programming)/RS485(or remote keypad) port (Lovato/Modbus RTU) + modem (SMS/email) or PC. Multilanguage (Italian, English, french, Spanish)

 
 Lovato 
Sstarter,ADX0190B,3phase,190A/90kW@414V,Incl contactor.  Sstarter,ADX0190B,3phase,190A/90kW@414V,Incl contactor.

ADX0190B - 3phase, 190Amp, 90kW@415v, 132kW@500V, Integrated bypass contactor, Aux supply 208 - 240Vac, +-10%, 50/60Hz Torque and current(350% -Normal duty/500% Heavy duty)/motor full load current) control. By overrating (up to 50% possible) the starter up to 700% of motor currents can be achieved. Time: Max starting=1000sec, delay for each trip condition. Auto restart, Analog 0/2-10V or 0/4-20mA ramp or start/stop control. Digital display and membrane keypad. Hi/Low Voltage, Current,asymmetry,Power factor, motor torque, Power, motor thermal status, Heatsink temperature, Alarms conditions, Time stamped Alarm/event log(last 20) displayed. Real time clock, Maintenance(operating hours) alarm, Phase failure, Reversal, Frequency out of limits. SCR and by-pass contactor malfunction check. For very frequent staring the bypass contactor phase can be disabled. INPUTS: start + programmable stop + programmable analog/digital + 1 analog 0/2-10 or 0/4-20mA(by adding 500 ohm resistor). OUTPUTS: 3 programmable relays + 1 global alarm relay. Comms port:RS232(programming)/RS485(or remote keypad) port (Lovato/Modbus RTU) + modem (SMS/email) or PC. Multilanguage (Italian, English, french, Spanish)

 
 Lovato 
Sstarter,ADX0245B,3phase,245A/132kW@414V,Incl contactor.  Sstarter,ADX0245B,3phase,245A/132kW@414V,Incl contactor.

ADX0245B - 3phase, 245Amp, 132kW@415v, 160kW@500V, Integrated bypass contactor, Aux supply 208 - 240Vac, +-10%, 50/60Hz Torque and current(350% -Normal duty/500% Heavy duty)/motor full load current) control. By overrating (up to 50% possible) the starter up to 700% of motor currents can be achieved. Time: Max starting=1000sec, delay for each trip condition. Auto restart, Analog 0/2-10V or 0/4-20mA ramp or start/stop control. Digital display and membrane keypad. Hi/Low Voltage, Current,asymmetry,Power factor, motor torque, Power, motor thermal status, Heatsink temperature, Alarms conditions, Time stamped Alarm/event log(last 20) displayed. Real time clock, Maintenance(operating hours) alarm, Phase failure, Reversal, Frequency out of limits. SCR and by-pass contactor malfunction check. For very frequent staring the bypass contactor phase can be disabled. INPUTS: start + programmable stop + programmable analog/digital + 1 analog 0/2-10 or 0/4-20mA(by adding 500 ohm resistor). OUTPUTS: 3 programmable relays + 1 global alarm relay. Comms port:RS232(programming)/RS485(or remote keypad) port (Lovato/Modbus RTU) + modem (SMS/email) or PC. Multilanguage (Italian, English, french, Spanish)

 
 Lovato