Other(not listed above) - ElectroSource
Other(not listed above)

Other(not listed above)

Product Attributes
                                                                                                   
Number of attributes100 gary test1
 Image   Products+   Manufacturer 
RHM,D3RHM1  RHM,D3RHM1

D3-RHM1 - Running hour meter(Lapsed time counter) Unit records the amount of hours it is powered and the run contacts are closed. Range: 9999 hours A setpoint can be set for relay to (de)energise Keypad and menu lock . Factory reset feature NO ROLLOVER FUNCTION - only reset Relay inverse function Run/Stop from terminals Reset via terminals - EEPROM memory - Permanent memory - Not effected when power off Crystal clock DIN mount Plug in terminals

 
 Icon Electronics 
RHM,P44RHM1  RHM,P44RHM1

P44-RHM1 - Running hour meter(Lapsed time counter) Unit records the amount of hours it is powered and the run contacts are closed. Range: 9999 hours A setpoint can be set for relay to (de)energise Keypad and menu lock . Factory reset feature NO ROLLOVER FUNCTION - only reset Relay inverse function Run/Stop from terminals Reset via terminals EEPROM memory - Permanent memory - Not effected when power off Crystal clock DIN mount Plug in terminals

 
 Icon Electronics 
RHM,P49RHM1  RHM,P49RHM1

P49-RHM1 - Running hour meter(Lapsed time counter) Unit records the amount of hours it is powered and the run contacts are closed. Range: 9999 hours A setpoint can be set for relay to (de)energise Keypad and menu lock . Factory reset feature NO ROLLOVER FUNCTION - only reset Relay inverse function Run/Stop from terminals Reset via terminals EEPROM memory - Permanent memory - Not effected when power off Crystal clock DIN mount Plug in terminals

 
 Icon Electronics 
Tacho,D3-RPM1  Tacho,D3-RPM1

D3 RPM1-: RPM(Count a digital signal) monitor, 4Digit - 2off 7segment displays, DIN module. Adjustable window can be set(Hi/Lo) in which relay energises. Common hysteresis setpoint. Input prescale feature (Counts a multiple pulses as one input) 10max Proximity NPN 3wire N/O sensor or mechanical switch. Adjustable startup delay- Fault monitoring disabled for this time period after power on. Programmable reaction delay time - Unit trips after this time delay since trip condition occurred. Latch and reset facility - Trip condition (relay deenergised) remains until reset(open latch) or recycle power. On board 24Vdc Power supply. Each fault condition is indicated on screen. Security: Complete lockout or partial lockout + Code protection. Factory default reset

 
 Icon Electronics 
Tacho,P44-RPM1  Tacho,P44-RPM1

P44-RPM1-: RPM(Count a digital signal) monitor, 4Digit - 1off 7segment displays, 48x48 Panelmount. Adjustable window can be set(Hi/Lo) in which relay energises. Common hysteresis setpoint. Input prescale feature (Counts a multiple pulses as one input) 10max Proximity NPN 3wire N/O sensor or mechanical switch. Adjustable startup delay- Fault monitoring disabled for this time period after power on. Programmable reaction delay time - Unit trips after this time delay since trip condition occurred. Latch and reset facility - Trip condition (relay deenergised) remains until reset(open latch) or recycle power. On board 24Vdc Power supply. Each fault condition is indicated on screen. Security: Complete lockout or partial lockout + Code protection. Factory default reset

 
 Icon Electronics 
Tacho,P49-RPM1  Tacho,P49-RPM1

P49-RPM1-: RPM(Count a digital signal) monitor, 4Digit - 1off 7segment displays, 96x48mm Panelmount. Adjustable window can be set(Hi/Lo) in which relay energises. Common hysteresis setpoint. Input prescale feature (Counts a multiple pulses as one input) 10max Proximity NPN 3wire N/O sensor or mechanical switch. Adjustable startup delay- Fault monitoring disabled for this time period after power on. Programmable reaction delay time - Unit trips after this time delay since trip condition occurred. Latch and reset facility - Trip condition (relay deenergised) remains until reset(open latch) or recycle power. On board 30Vdc Power supply. Each fault condition is indicated on screen. Security: Complete lockout or partial lockout + Code protection. Factory default reset

 
 Icon Electronics