Timers - ElectroSource
Timers

Timers

Product Attributes
                                                                                                   
Number of attributes100
Show: 
gary test1
 Image   Products+   Manufacturer 
mVmon,D3-CMD0/1/2 (-T)  mVmon,D3-CMD0/1/2 (-T)

D3-CMD0/1/2 (-T)-: DC 50mV (Shunt) Voltage monitor, 4Digit - 2off 7segment displays, 35mm DIN module. Adjustable window can be set(Hi/Lo) in which each relay will energise. Hi and Lo hysterises setpoints. Input is scalable(1500) and up to 3 decimal places. Input signal damping Each relay can be set with own trip conditions. Adjustable startup delay per relay- Fault monitoring disbabled for this time after power on. Adjustable reaction delay per relay- The trip delay time after the fault has occured. Relay invert status functionality. Can latch one or both relays. 4-20mA output for -T models. (0-10V on special request) Each fault condition is indicated on screen. Records Max/Min values in the last 24Hrs - updated every 60minutes. Security: Complete lockout or partial lockout + Code protection. Factory default reset

 
 Icon Electronics 
Timer,D3 CWT1  Timer,D3 CWT1

D3-CWT1 - Clockwork timer, 4Digit - 2off 7segment displays, DIN mount. Preset times ranges - 0-99 min OR 0-99 hours. Start from front panel or terminal control. Relay energises for the programmed time(Delay OFF). Aux. resets cycle at any time. The display indicates the remaining time. Continues where it was after a power failure Security -Full(Nothing can be changed) or partial(Setpoint can be changed) lock or open from front panel + code protect Factory default reset

 
 Icon Electronics 
Timer,D3-MFT1  Timer,D3-MFT1

P44-MFT1 - Digital 2 x 7segment displays; DIN mount, (1)On delay - powerup, (2)On delay - pulse triggered. Pulses during timing immaterial. (3)Interval - powerup, (4)Interval - pulse triggered. Starts timing cycle -further pulses during timing will not affect time. Reset only works after timed out. (5)Repeating - On&off programmable time. Range: (1)Hours and minutes - 99Hours : 59sec (2)Minutes and seconds. - 59Mins : 59sec With "Save" function activated timing will continue from where it left off after a power failure. Display remaining or elapsed time. Lock can have only setpoint available or CODE all locked. Factory reset & security code reset With "Save" function activated timing will continue from where it left off after a power failure.

 
 Icon Electronics 
Timer,D3ACT1 - Acumulation timer  Timer,D3ACT1 - Acumulation timer

D3-ACT1 = Accumulation timer + count.4digit- 2off 7segment displays. Din mount Plugin terminals Every pulse increments the timer by a programmable amount of time. Number of counts is recorded in resettable and NON-resettable registers. Range 99: 59: 59 hours and the max number of counts = 9999. The relay is energised whenever the timer is NOT EQUAL TO ZERO. A seperate relay can be set to energise when remaining time falls below pre-programmed time. "Save" function ensures continuous operation after power failure (carries on where it left off). Unit can be locked - Full or reduced menus+ code protect

 
 Icon Electronics 
Timer,DDT Defrost timer  Timer,DDT Defrost timer

DDT Defrost timer – Selectable 4 or 8 hours cycle. Defrost and Fan delay periods, 35mm Din mount. Separate Defrost(3-60minutes) and FAN delay(0.3 to 60,minutes) periods can be set. Power on and Defrost/Fan active LED indicators. At power up the DEFROST relay energises for an adjustable (3-60min) timing period. Thereafter the adjustable COOLING starts (3-60sec) after which the FAN relay energises. Closing a contact activates the COOLING cycle directly (terminating the DEFROST cycle) Defrost delay overide facility

 
 ElectroDev 
Timer,DEF1/F Defrost timer  Timer,DEF1/F Defrost timer

DDT Defrost timer – Selector switch and pot control, 11pin base mount. Power on and Defrost/Fan active LED indicators. At power up the DEFROST relay energises for an adjustable (3-60min) timing period. Thereafter the adjustable COOLING starts (3-60sec) after which the FAN relay energises. Closing a contact activates the COOLING cycle directly (terminating the DEFROST cycle)

 
 ElectroDev 
Timer,DMFT1- ProgRange+8Function timer  Timer,DMFT1- ProgRange+8Function timer

DMFT1 - Potentiometer / selector switch adjustments. DIN mount, Operating modes: On-delay Interval Equal Pulse controlled Pulse controlled Step relay Pulse generator On/off delay Program Ranges: 6sec 60sec 6min 60min 6hrs 60hrs

 
 ElectroDev 
Timer,DMFT1/V -8Function TMR+12-260Vac  Timer,DMFT1/V -8Function TMR+12-260Vac

DMFT1/V - Potentiometer / selector switch adjustments. DIN mount, Operating modes: On-delay Interval Equal Pulse controlled Pulse controlled Step relay Pulse generator On/off delay Program Ranges: 6sec 60sec 6min 60min 6hrs 60hrs

 
 ElectroDev 
Timer,DMSA- Multi start attempt relay  Timer,DMSA- Multi start attempt relay

DMSA - Multi start attempt relay – Controls the cranking of engine. Programmable number of attempts (3-8) and if it fails to start the engine then an alarm relay actives. Cranking time adjustable 0 to 30sec. Waiting time between starts 0 to 30sec Removal of power to the unit completes the cycle.

 
 ElectroDev 
Timer,DOD - De-energisation timer  Timer,DOD - De-energisation timer

DOD - Delay On De-energisation timer Relay ON during power up. Time duration starts on removal of power, On completion of delay relay de-energises. Applying power during delay time will reset timer and relay stays on. Beware: Pulses must be longer than 30sec Power must be applied for a minimum of 30% of programmed time.

 
 ElectroDev 
Timer,DSD - star-delta timer  Timer,DSD - star-delta timer

DSD – Programmable Star / delta timer (up to 60sec) - with adjustable(40-180msec)intermediate / transition time (relay off) between star and delta.

 
 ElectroDev 
Timer,DUR - Unequal repeating timer  Timer,DUR - Unequal repeating timer

DUR – Unequal (assymetrical) repeating timer. A preset range - 0.3sec to 60minutes - of various ON/OFF times can be selected and each time ON/OFF can be fine tuned with potentiometer according to requirement. Terminal link determines if relay energised in ON time or OFF time periods.

 
 ElectroDev 
Timer,G10- Multi start attempt relay  Timer,G10- Multi start attempt relay

G10 - Multi start attempt relay – Manages the cranking of engine. After 3 attempts and the power is not removed ( ) the alarm relay actives. One adjustment setting for both Crank and Wait/Dwel/Pause time : 1-30sec

 
 ElectroDev 
Timer,P44-CWT1  Timer,P44-CWT1

P44-CWT1 - Clockwork timer, 4Digir - 2off 7segment displays, 48x48mm Panel mount. Preset times ranges - 0-99 min OR 0-99 hours. Start from front panel or terminal control. Relay energises for the programmed time. Aux. resets cycle at any time. The display indicates the remaining time. Continues where it was after a power failure Security -Full(Nothing can be changed) or partial(Setpoint can be changed) lock or open from front panel + code protect Factory default reset

 
 Icon Electronics 
Timer,P44-MFT1  Timer,P44-MFT1

P44-MFT1 - Digital 2 x 7segment displays; DIN mount, (1)On delay - powerup, (2)On delay - pulse triggered (2)Interval - powerup, (3)Interval - pulse triggered (3)Repeating - On&off programmable time. Range: (1)Hours and minutes (2)Minutes and seconds. With "Save" function activated timing will continue from where it left off after a power failure. Display remining or eleapsed time. Lock can have only setpoint available or CODE all locked. Factory reset & security code reset With "Save" function activated timing will continue from where it left off after a power failure.

 
 Icon Electronics 
Timer,P44ACT1 - Acumulation timer  Timer,P44ACT1 - Acumulation timer

P44-ACT1 = Accumulation timer + counter.4digit- 2off 7segment displays. 48x48mm Panelmount Plugin terminals Every pulse increments the timer by a programmable amount of time. Number of counts is recorded in resettable and NON-resettable registers. Range 99: 59: 59 hours and the max number of counts = 9999. The relay is enegised whenever the timer is NOT EQUAL TO ZERO. A seperate relay can be set to energise when remaining time falls below pre-programmed time. "Save" function ensures continuous operation after power failure (carries on where it left off). Unit can be locked - Full or reduced menus+ code protect

 
 Icon Electronics 
Timer,P49-CWT1  Timer,P49-CWT1

P49-CWT1 - Clockwork timer, 4Digir - 1off 7segment display, 96x48mm Panel mount. Preset times ranges - 0-99 min OR 0-99 hours. Start from front panel or terminal control. Relay energises for the programmed time. Aux. resets cycle at any time. The display indicates the remaining time. Continues where it was after a power failure Security -Full(Nothing can be changed) or partial(Setpoint can be changed) lock or open from front panel+ code protect Factory default reset

 
 Icon Electronics 
Timer,P49-MFT1  Timer,P49-MFT1

P49-MFT1 - Digital 2 x 7segment displays; DINl mount, (1)On delay - powerup, (2)On delay - pulse triggered (3)Interval - powerup, (4)Interval - pulse triggered (5)Repeating - On&off programmable time. Range: (1)Hours and minutes (2)Minutes and seconds. With "Save" function activated timing will continue from where it left off after a power failure. Display remining or eleapsed time. Lock can have only setpoint available or CODE all locked. Factory reset & security code reset With "Save" function activated timing will continue from where it left off after a power failure.

 
 Icon Electronics 
Timer,P49ACT1 - Acumulation timer  Timer,P49ACT1 - Acumulation timer

P49-ACT1 = Accumulation timer + count.4digit- 2off 7segment displays. 96x48mm panelmount Plugin terminals Every pulse increments the timer by a programmable amount of time. Number of counts is recorded in resettable and NON-resettable registers. Range 99: 59: 59 hours and the max number of counts = 9999. The relay is enegised whenever the timer is NOT EQUAL TO ZERO. A seperate relay can be set to energise when remaining time falls below pre-programmed time. "Save" function ensures continuous operation after power failure (carries on where it left off). Unit can be locked - Full or reduced menus+ code protect

 
 Icon Electronics 
Timer,R2U - Unequal repeating timer  Timer,R2U - Unequal repeating timer

R2U – Unequal (assymetrical) repeating timer. A preset range - 0.3sec to 60Hrs - of various ON/OFF times can be selected and each time ON/OFF can be fine tuned with potentiometer according to requirement. Terminal link determines if relay energised in ON time or OFF time periods.

 