CNT,D3 CNT(0/1)  CNT,D3 CNT(0/1)

D3-CNT0/1 - Counter/ Frequency counter, 4Digit - 2off 7segment displays, DIN mount. 1-49999 (The decimal indicates values higher than 4 digits) On frequency a window can be set from setpoint -Hysteris 0-50% Prescaler-200max- Reads qty counts before incrimenting 1 PostScaler max 200 - each count equals this number Diplay either lapsed or remaining counts or frequency Invert relay function. Count output can latch on reaching setpoint or auto reset pulse 0.1 99.9sec. Built in Vdc power supply. Signal can be set for either on or off NPN sensor can be used Input pulse speed slow/fast Can be set to continue where it was after a power failure Security -Full(Everything locked),partial(Setpoint can be set) lock or open from front panel Terminal reset Crystal clock EEProm memory

 
 Icon Electronics 
CNT,P44 CNT(0/1)  CNT,P44 CNT(0/1)

P44-CNT0/1 - Counter/ Frequency counter, 4Digit - 2off 7segment displays, Panel mount. 1-49999 (The decimal indicates values higher than 4 digits) On frequency a window can be set from setpoint -Hysteris 0-50% Prescaler-200max- Reads qty counts before incrimenting 1 PostScaler=200max - Each count equals this number Diplay either lapsed or remaining counts or frequency Invert relay function. Count output can latch on reaching setpoint or auto reset pulse 0.1 99.9sec. Built in Vdc power supply. Signal can be set for either on or off NPN sensor can be used Input pulse speed slow/fast Can be set to continue where it was after a power failure Security -Full(Everything locked),partial(Setpoint can be set) lock or open from front panel Terminal reset Crystal clock EEProm memory

 
 Icon Electronics 
CNT,P49 CNT(0/1)  CNT,P49 CNT(0/1)

P49-CNT0/1 - Counter/ Frequency counter, 4Digir - 1off 7segment displays, 96x48 panelmount. 1-49999 (The decimal indicates values higher than 4 digits) On frequency a window can be set from setpoint -Hysteris 0-50% Prescaler-200max- Reads qty counts before incrimenting 1 PostScaler max 200 - each count equals this number Diplay either lapsed or remaining counts or frequency Invert relay function. Count output can latch on reaching setpoint or auto reset pulse 0.1 99.9sec. Built in Vdc power supply. Signal can be set for either on or off NPN sensor can be used Input pulse speed slow/fast Can be set to continue where it was after a power failure Security -Full(Everything locked),partial(Setpoint can be set) lock or open from front panel Terminal reset Crystal clock EEProm memory

 
 Icon Electronics 
Freq,DFM- Frequency monitor.  Freq,DFM- Frequency monitor.

DFM:- 45- 56Hz Over/Under OWN supply frequency monitor. Selectable time delays, Latch, 35mmDIN, 2x SPDT relays. *Microprocessor control. Four selectable delay modes: *During timing period the power LED flashes. 1. No delay. 2. 10 sec power up delay - Does not monitor fault for first 10 seconds after power up. 3. 180 recovery delay- waits 180 sec at power up before relay energise. 180sec time delay before relay can activate again. 4. 10second response delay - Trips 10sec after fault occurred, *Relay energised is the normal state of the unit. Over Frequency:- (50,51,52,53,54,55 settings) Voltage higher then setpoint the relay will de-energise. The relay will only energise again after the voltage has dropped by the hysteresis amount. Under Frequency:- (45,46,47,48,49,50Hz settings) Voltage lower then the setpoint will de-energise relay. The relay will only energise again if the voltage has risen by the hysteresis amount. Latch function- Terminal reset. *2 LEDS indicate high or low trip.

 
 ElectroDev 
Tacho,D3-RPM1  Tacho,D3-RPM1

D3 RPM1-: RPM(Count a digital signal) monitor, 4Digit - 2off 7segment displays, DIN module. Adjustable window can be set(Hi/Lo) in which relay energises. Common hysteresis setpoint. Input prescale feature (Counts a multiple pulses as one input) 10max Proximity NPN 3wire N/O sensor or mechanical switch. Adjustable startup delay- Fault monitoring disabled for this time period after power on. Programmable reaction delay time - Unit trips after this time delay since trip condition occurred. Latch and reset facility - Trip condition (relay deenergised) remains until reset(open latch) or recycle power. On board 24Vdc Power supply. Each fault condition is indicated on screen. Security: Complete lockout or partial lockout + Code protection. Factory default reset

 
 Icon Electronics 
Tacho,DTM-Tachometer  Tacho,DTM-Tachometer

DTM - Tachometer Select Over/Under speed detection. Sensor PNP 3wire normal open. 4 speed ranges: 1–10Rpm 10-100Rpm 100-1000Rpm 100-1000Rpm 1000-10000Rpm. A pot finetunes the monitor setpoint

 
 ElectroDev 
Tacho,P44-RPM1  Tacho,P44-RPM1

P44-RPM1-: RPM(Count a digital signal) monitor, 4Digit - 1off 7segment displays, 48x48 Panelmount. Adjustable window can be set(Hi/Lo) in which relay energises. Common hysteresis setpoint. Input prescale feature (Counts a multiple pulses as one input) 10max Proximity NPN 3wire N/O sensor or mechanical switch. Adjustable startup delay- Fault monitoring disabled for this time period after power on. Programmable reaction delay time - Unit trips after this time delay since trip condition occurred. Latch and reset facility - Trip condition (relay deenergised) remains until reset(open latch) or recycle power. On board 24Vdc Power supply. Each fault condition is indicated on screen. Security: Complete lockout or partial lockout + Code protection. Factory default reset

 
 Icon Electronics 
Tacho,P49-RPM1  Tacho,P49-RPM1

P49-RPM1-: RPM(Count a digital signal) monitor, 4Digit - 1off 7segment displays, 96x48mm Panelmount. Adjustable window can be set(Hi/Lo) in which relay energises. Common hysteresis setpoint. Input prescale feature (Counts a multiple pulses as one input) 10max Proximity NPN 3wire N/O sensor or mechanical switch. Adjustable startup delay- Fault monitoring disabled for this time period after power on. Programmable reaction delay time - Unit trips after this time delay since trip condition occurred. Latch and reset facility - Trip condition (relay deenergised) remains until reset(open latch) or recycle power. On board 30Vdc Power supply. Each fault condition is indicated on screen. Security: Complete lockout or partial lockout + Code protection. Factory default reset

 