Product Attributes
                                                                                                   
Number of attributes100 gary test1
 Image   Products+   Manufacturer 
Meter,D3 VM1(0/1/2) (-T)  Meter,D3 VM1(0/1/2) (-T)

D3-VM0/1/2 - Own supply 300Vac RMS monitor, 4Digit - 2off 7segment displays, DIN mount. EACH relay own high,low and hysterisys setpoints. Input is scalable from 5 to 3500 and decimal point can be set for any position. Front panel calibration +-10% up Startup delay programmable time(100sec). Reaction delay programmable time(100sec). Latch facility Terminals reset Security -Full(Nothing can be changed) or Reduced menu(Setpoint can be changed) lock or open from front panel + code protect Factory default reset

 
 Icon Electronics 
Meter,D3 VM3(0/1/2) (-N)  Meter,D3 VM3(0/1/2) (-N)

D3-VM30/1/2 (N) (-T) - Own supply 500Vac RMS Voltage and Frequency monitor, 4Digit - 2off 7segment displays, DIN mount. Adjustable Each relay - Separate VOLTAGE and FREQUENCY Over/Under trip setpoints with common hysterises,Phase imbalance and trip setpoint + hysterisis adjustment. Each of these fault conditions can be disabled. Phase rotation check(Not disable). *The -N version monitors neutral loss. Input is scalable from 5 to 3500(steps of 5) and decimal point can be set for any position. Front panel calibration +-10% up Each relay can be set with own trip setpoints. Adjustable startup delay- Fault monitoring disbabled for this time after power on.(100sec) Adjustable reaction delay- The trip delay time after the fault has occured.(100sec) Latch + Terminal reset facility 4-20mA output for -T models. (0-10V on special request) Each fault condition is indicated on screen. Security: Complete lockout or partial lockout.+ code protect Factory default reset

 
 Icon Electronics 
Meter,P44 VM1(0/1/2) (-T)  Meter,P44 VM1(0/1/2) (-T)

P44-VM0/1/2 - Own supply, 300Vac RMS monitor, 4Digit - 2off 7segment displays, 48x48mm Panel mount. EACH relay own high,low and hysterisys setpoints. Input is scalable from 5 to 3500 and decimal point can be set for any position. Front panel calibration +-10% up Startup delay programmable time(100sec). Reaction delay programmable time(100sec). Latch facility Terminals reset Security -Full(Nothing can be changed) or Reduced menu(Setpoint can be changed) lock or open from front panel + code protect Factory default reset

 
 Icon Electronics 
Meter,P44 VM3(0/1/2) (-N) (-T)  Meter,P44 VM3(0/1/2) (-N) (-T)

P44-VM30/1/2 (N) (-T) - Own supply 500Vac RMS Voltage and Frequency monitor, 4Digit - 1off 7segment display, 48x48mm Panelmount. Adjustable Each relay - Separate VOLTAGE and FREQUENCY Over/Under trip setpoints with common hysterises,Phase imbalance and trip setpoint + hysterisis adjustment. Each of these fault conditions can be disabled. Phase rotation check(Not disable). *The -N version monitors neutral loss. Input is scalable from 5 to 3500(steps of 5) and decimal point can be set for any position. Front panel calibration +-10% up Each relay can be set with own trip setpoints. Adjustable startup delay- Fault monitoring disbabled for this time after power on.(100sec) Adjustable reaction delay- The trip delay time after the fault has occured.(100sec) Latch + Terminal reset facility 4-20mA output for -T models. (0-10V on special request) Each fault condition is indicated on screen. Security: Complete lockout or partial lockout.+ code protect Factory default reset

 
 Icon Electronics 
Meter,P49 VM1(0/1/2) (-T)  Meter,P49 VM1(0/1/2) (-T)

P49-VM0/1/2 - Own supply 300Vac RMS monitor, 4Digit - 1off 7segment displays, 96x48mm Panelmount. EACH relay own high,low and common hysteresis setpoints. Input is scalable from 5 to 3500 and decimal point can be set for any position. Front panel calibration +-10% up Startup delay programmable time(100sec). Reaction delay programmable time(100sec). Latch facility Terminals reset Security -Full(Nothing can be changed) or Reduced menu(Setpoint can be changed) lock or open from front panel + code protect Factory default reset

 
 Icon Electronics 
Meter,P49 VM3(0/1/2) (-N)  Meter,P49 VM3(0/1/2) (-N)

P49-VM30/1/2 (N) (-T) - Own supply 500Vac RMS Voltage and Frequency monitor, 4Digit - 1off 7segment displays, 96x48mm Panelmount. Adjustable Each relay - Separate VOLTAGE and FREQUENCY Over/Under trip setpoints with common hysterises,Phase imbalance and trip setpoint + hysterisis adjustment. Each of these fault conditions can be disabled. Phase rotation check(Not disable). *The -N version monitors neutral loss. Input is scalable from 5 to 3500(steps of 5) and decimal point can be set for any position. Front panel calibration +-10% up Each relay can be set with own trip setpoints. Adjustable startup delay- Fault monitoring disbabled for this time after power on.(100sec) Adjustable reaction delay- The trip delay time after the fault has occured.(100sec) Latch + Terminal reset facility 4-20mA output for -T models. (0-10V on special request) Each fault condition is indicated on screen. Security: Complete lockout or partial lockout.+ code protect Factory default reset

 