ElectroDev - ElectroSource
ElectroDev

ElectroDev

Product Attributes
                                                                                                   
Number of attributes100
Show: 
gary test1
 Image   Products+   Manufacturer 
9013.4_Panelmount flylead socket 9013.4_Panelmount flylead socket

9013.4 Panelmount flylead 11pin socket

 ElectroDev 
9013_Panelmount 11pin socket 9013_Panelmount 11pin socket

9013 Panelmount 11pin socket. Solder connect

 ElectroDev 
9015_PCB mount 11pin socket 9015_PCB mount 11pin socket

9015 PCB mount 11pin socket

 ElectroDev 
Ammeter,LA5/1 - 5Amp Hi/Lo current monitor Ammeter,LA5/1 - 5Amp Hi/Lo current monitor

LA5/P:- 1-5Amp UNDER CURRENT, 1phase AC current monitor. Adjustable setpoint and reponse delay.Reset button, 11pin plug in relay, 1x SPDT relay. One 1amp CT for input. Preset 5% hysteresis. *During timing period the power LED flashes. 10 sec power up delay - Does not monitor fault for first 10 seconds after power up. Adjustable 0.5 - 30minutes response delay. Under current:- Current lower then the setpoint will de-energise relay. The relay will only energise again if the voltage has risen by the hysteresis amount. Button reset on faceplate or cycle power.

 ElectroDev 
Ammeter,LA5/1P - 1Amp lo current monitor Ammeter,LA5/1P - 1Amp lo current monitor

LA5/P:- 5Amp UNDER CURRENT, 1phase AC current monitor. Adjustable setpoint and reponse delay.Reset button, 11pin plug in relay, 1x SPDT relay. One 1amp CT for input. Preset 5% hysteresis. *During timing period the power LED flashes. 10 sec power up delay - Does not monitor fault for first 10 seconds after power up. Adjustable 0.5 - 30minutes response delay. Under current:- Current lower then the setpoint will de-energise relay. The relay will only energise again if the current has risen by the hysteresis amount. Button reset on faceplate or cycle power.

 ElectroDev 
Ammeter,LA5/5 - 1Amp Hi/Lo current monitor Ammeter,LA5/5 - 1Amp Hi/Lo current monitor

LA5/P:- 1-5Amp UNDER CURRENT, 1phase AC current monitor. Adjustable setpoint and reponse delay.Reset button, 11pin plug in relay, 1x SPDT relay. One 5amp CT for input. Preset 5% hysteresis. *During timing period the power LED flashes. 10 sec power up delay - Does not monitor fault for first 10 seconds after power up. Adjustable 0.5 - 30minutes response delay. Under current:- Current lower then the setpoint will de-energise relay. The relay will only energise again if the voltage has risen by the hysteresis amount. Button reset on faceplate or cycle power.

 ElectroDev 
Ammeter,LA5/5P - 5Amp current monitor Ammeter,LA5/5P - 5Amp current monitor

LA5/P:- 1-5Amp UNDER CURRENT, 1phase AC current monitor. Adjustable setpoint and reponse delay.Reset button, 11pin plug in relay, 1x SPDT relay. One 5amp CT for input. Preset 5% hysteresis. *During timing period the power LED flashes. 10 sec power up delay - Does not monitor fault for first 10 seconds after power up. Adjustable 0.5 - 30minutes response delay. Under current:- Current lower then the setpoint will de-energise relay. The relay will only energise again if the voltage has risen by the hysteresis amount. Button reset on faceplate or cycle power.

 ElectroDev 
Ammeter,WA5/1: 1Amp AC current window monitor Ammeter,WA5/1: 1Amp AC current window monitor

WA5:- 0-5Amp window current monitor, 1phase AC current monitor. Adjustable High and Low trip setpoints.Latch, 11pin module,1x SPDT relay. One 1amp CT for input. Preset 5% hysteresis. 10 sec power up delay - Does not monitor fault for first 10 seconds after power up. 2 modes of operation: 1.Relay activated as long as the current is between the High and Low setpoints. If tripped relay energises again if current changed by more than hysterises (5%) into window parameters -Unless latched off used. 2. Relay de-energised whilst current level between window setpoints. If tripped relay de-energises again if current changed by more than hysterises (5%) into window parameters -Unless latched off used. Latch function- Terminal reset.

 ElectroDev 
Ammeter,WA5/5: 5Amp AC current window monitor Ammeter,WA5/5: 5Amp AC current window monitor

WA5:- 0-5Amp window current monitor, 1phase AC current monitor. Adjustable High and Low trip setpoints.Latch, 11pin module,1x SPDT relay. One 5amp CT for input. Preset 5% hysteresis. 10 sec power up delay - Does not monitor fault for first 10 seconds after power up. 2 modes of operation: 1.Relay activated as long as the current is between the High and Low setpoints. If tripped relay energises again if current changed by more than hysterises (5%) into window parameters -Unless latched off used. 2. Relay de-energised whilst current level between window setpoints. If tripped relay de-energises again if current changed by more than hysterises (5%) into window parameters -Unless latched off used. Latch function- Terminal reset.

 ElectroDev 
ES11/G_11pin DIN mount socket ES11/G_11pin DIN mount socket

ES11/G 11pin grey DIN + screw/surface mount socket

 ElectroDev 
EX01_Retaining clip for plugin modules EX01_Retaining clip for plugin modules

EX01Retaining clip for plugin modules

 ElectroDev 
EX02_Panelmount adapter EX02_Panelmount adapter

EX02 Panel mount adaptor frame for 11pin plugin boxes

 ElectroDev 
Freq,DFM- Frequency monitor. Freq,DFM- Frequency monitor.

DFM:- 45- 56Hz Over/Under OWN supply frequency monitor. Selectable time delays, Latch, 35mmDIN, 2x SPDT relays. *Microprocessor control. Four selectable delay modes: *During timing period the power LED flashes. 1. No delay. 2. 10 sec power up delay - Does not monitor fault for first 10 seconds after power up. 3. 180 recovery delay- waits 180 sec at power up before relay energise. 180sec time delay before relay can activate again. 4. 10second response delay - Trips 10sec after fault occurred, *Relay energised is the normal state of the unit. Over Frequency:- (50,51,52,53,54,55 settings) Voltage higher then setpoint the relay will de-energise. The relay will only energise again after the voltage has dropped by the hysteresis amount. Under Frequency:- (45,46,47,48,49,50Hz settings) Voltage lower then the setpoint will de-energise relay. The relay will only energise again if the voltage has risen by the hysteresis amount. Latch function- Terminal reset. *2 LEDS indicate high or low trip.

 ElectroDev 
HYB010H HYB010H

HYB010H,3pole,Straight connector

 ElectroDev 
HYB010H HYB010H

HYB010H,4pole,Spreader connector

 ElectroDev 
Level,DLL 3Probe conductive liquid level LO/HI control Level,DLL 3Probe conductive liquid level LO/HI control

DLL – 3 probe Liquid level Control 3 Modes of operation:- 1. Emptying :– Making the MAX level contact (The MIN should be made as well) energises the relay. Relay de-energises when MIN opens (MAX should not be made at this time). 2. Filling :– MIN and MAX open energises relay. Relay DE-energises when MAX is made. 3. Single level /Tank full control:- *Permanent short /close Low terminal. Emptying:-The relay operates when high closes. Filling:- The relay de-activates (releases) when high closes.

 ElectroDev 
Level,DLL4- Hi/Lo and Hi/Lo Alarm control Level,DLL4- Hi/Lo and Hi/Lo Alarm control

DLL4 - 5 probe conductive liquid level control. 35mm DIN mount, 2 x SPDT relays. High, High alarm, Low, Low Alarm inputs. Adjustable sensitivity(0-80 kohm) and response delay(0-10 sec) times. Control modes 1: Emptying with Alarm 2. Filling with Alarm 3. Emptying with pump priority 4. Filling with pump priority 5. Container filling and well draining with alarm 6. Electrode test *This should be detailed by an actual test to confirm operation – text is confusing if not wrong!

 ElectroDev 
Level,LV1:- 3Probe conductive liquid level Fill/Empty control Level,LV1:- 3Probe conductive liquid level Fill/Empty control

LV1 – 2/3probe Liquid level Control. Sensitivity adjustment. 3 Modes of operation:- 1. Emptying :– Making the MAX level contact (The MIN should be made as well) energises the relay. Relay de-energises when MIN opens (MAX should not be made at this time). 2. Filling :– MIN and MAX open energises relay. Relay DE-energises when MAX is made. 3. Single level /Tank full control:- *Permanent short /close Low terminal. Emptying:-The relay operates when high closes. Filling:- The relay de-activates (releases) when high closes.

 ElectroDev 
Level,LVC1:- 1/2Level switch ctl,Fill/Empty/Full control, NPN-NO,11pin Level,LVC1:- 1/2Level switch ctl,Fill/Empty/Full control, NPN-NO,11pin

LVC1 – 2/3probe Liquid level Control. Sensitivity adjustment. 3 Modes of operation:- Filling: Both High/Low probes open the relay is energized. If the level reaches the HIGH probe the relay will de-energize. If the LOW probe opens again the relay will energise. Emptying: Both High/Low probes open the relay is de-energized. If HIGH probe is made the relay will energize and will remain ON until the level falls below the LOW level probe. Single level/Tank full control:- *Permanent short /close Low terminal. Emptying:-The relay operates when high closes. Filling:- The relay de-activates (releases) when high closes. Onboard 24Vdc PSU

 ElectroDev 
Oload,DPP1- 1phase Pump protection relay Oload,DPP1- 1phase Pump protection relay

DPP1 – Single phase pump monitoring relay. Unit is calibrated by pressing the SET button during normal load conditions. Recalibrate:-Press the SET button (until Power LED stops flashing) whilst applying power. Tolerance can be extended by continued press of SET button. Start-up 10sec delay provided. Fault reset is done by pressing SET button (Latched fault condition). 3 resets per 15minutes. Monitored conditions: Over-voltage 15% Under-voltage 15% Over-current – After 3 trips with 10 second pauses the unit goes into a tripped state only reset by cycling power. Under-current - By monitoring V/I phase-angle lag. Restarts AFTER the set recovery delay time. Phase reversal Override ON Pump running Un-calibrated

 ElectroDev