CNT,D3 CNT(0/1) CNT,D3 CNT(0/1)

D3-CNT0/1 - Counter/ Frequency counter, 4Digit - 2off 7segment displays, DIN mount. 1-49999 (The decimal indicates values higher than 4 digits) On frequency a window can be set from setpoint -Hysteris 0-50% Prescaler-200max- Reads qty counts before incrimenting 1 PostScaler max 200 - each count equals this number Diplay either lapsed or remaining counts or frequency Invert relay function. Count output can latch on reaching setpoint or auto reset pulse 0.1 99.9sec. Built in Vdc power supply. Signal can be set for either on or off NPN sensor can be used Input pulse speed slow/fast Can be set to continue where it was after a power failure Security -Full(Everything locked),partial(Setpoint can be set) lock or open from front panel Terminal reset Crystal clock EEProm memory

 Icon Electronics 
CNT,P44 CNT(0/1) CNT,P44 CNT(0/1)

P44-CNT0/1 - Counter/ Frequency counter, 4Digit - 2off 7segment displays, Panel mount. 1-49999 (The decimal indicates values higher than 4 digits) On frequency a window can be set from setpoint -Hysteris 0-50% Prescaler-200max- Reads qty counts before incrimenting 1 PostScaler=200max - Each count equals this number Diplay either lapsed or remaining counts or frequency Invert relay function. Count output can latch on reaching setpoint or auto reset pulse 0.1 99.9sec. Built in Vdc power supply. Signal can be set for either on or off NPN sensor can be used Input pulse speed slow/fast Can be set to continue where it was after a power failure Security -Full(Everything locked),partial(Setpoint can be set) lock or open from front panel Terminal reset Crystal clock EEProm memory

 Icon Electronics 
CNT,P49 CNT(0/1) CNT,P49 CNT(0/1)

P49-CNT0/1 - Counter/ Frequency counter, 4Digir - 1off 7segment displays, 96x48 panelmount. 1-49999 (The decimal indicates values higher than 4 digits) On frequency a window can be set from setpoint -Hysteris 0-50% Prescaler-200max- Reads qty counts before incrimenting 1 PostScaler max 200 - each count equals this number Diplay either lapsed or remaining counts or frequency Invert relay function. Count output can latch on reaching setpoint or auto reset pulse 0.1 99.9sec. Built in Vdc power supply. Signal can be set for either on or off NPN sensor can be used Input pulse speed slow/fast Can be set to continue where it was after a power failure Security -Full(Everything locked),partial(Setpoint can be set) lock or open from front panel Terminal reset Crystal clock EEProm memory

 Icon Electronics 
mAmon,D3 LM(0/1/2) (-T) mAmon,D3 LM(0/1/2) (-T)

D3-LM0/1/2 -: 0 / 4 to 20mA LOOP monitor, 4Digit - 2off 7segment displays, DIN mount. Adjustable window can be set(Hi/Lo) in which relay will energise. Hi and Lo hysterises setpoints. Each fault condition can be disabled. Input is scalable(1500) and decimal point up to 3 places. Each relay can be set with own trip conditions. Adjustable startup delay per relay- Fault monitoring disbabled for this time after power on. (100sec) Adjustable reaction delay per relay- The trip delay time after the fault has occured(100sec). Relay invert status functionality. Can latch one or both relays. Terminal reset. Input signal damping. 4-20mA output for -T models. (0-10V on special request) The 4 -20mA transmitted signal is optically isolated from the input signal The 4 -20mA can be inverted (decreases when input signal increase and vice versa). Onboard 24Vdc /30mA power supply for version -P. Each fault condition is indicated on screen. Records Max/Min values in the last 24Hrs - updated every 60minutes. Security: Complete lockout or partial lockout(only setpoint can be changed) + Code protection. Factory default reset

 Icon Electronics 
mAmon,D3 LM(0/1/2) (-T) mAmon,D3 LM(0/1/2) (-T)

D3-LM0/1/2 -: 0 / 4 to 20mA LOOP monitor, 4Digit - 2off 7segment displays, DIN mount. Adjustable window can be set(Hi/Lo) in which relay will energise. Hi and Lo hysterises setpoints. Each fault condition can be disabled. Input is scalable(1500) and decimal point up to 3 places. Each relay can be set with own trip conditions. Adjustable startup delay per relay- Fault monitoring disbabled for this time after power on. (100sec) Adjustable reaction delay per relay- The trip delay time after the fault has occured(100sec). Relay invert status functionality. Can latch one or both relays. Terminal reset. Input signal damping. 4-20mA output for -T models. (0-10V on special request) The 4 -20mA transmitted signal is optically isolated from the input signal The 4 -20mA can be inverted (decreases when input signal increase and vice versa). Onboard 24Vdc /30mA power supply for version -P. Each fault condition is indicated on screen. Records Max/Min values in the last 24Hrs - updated every 60minutes. Security: Complete lockout or partial lockout(only setpoint can be changed) + Code protection. Factory default reset

 Icon Electronics 
mAmon,P44 LM(0/1/2) (-T) mAmon,P44 LM(0/1/2) (-T)

P44-LM0/1/2 -: 0 / 4 to 20mA LOOP monitor, 4Digit - 2off 7segment displays, 48 x48 Panelmount. Adjustable window can be set(Hi/Lo) in which relay will energise. Hi and Lo hysterises setpoints. Each fault condition can be disabled. Input is scalable(1500) and decimal point up to 3 places. Each relay can be set with own trip conditions. Adjustable startup delay per relay- Fault monitoring disbabled for this time after power on. (100sec) Adjustable reaction delay per relay- The trip delay time after the fault has occured(100sec). Relay invert status functionality. Can latch one or both relays. Terminal reset. Input signal damping. 4-20mA output for -T models. (0-10V on special request) The 4 -20mA transmitted signal is optically isolated from the input signal The 4 -20mA can be inverted (decreases when input signal increase and vice versa). Onboard 24Vdc /30mA power supply for version -P. Each fault condition is indicated on screen. Records Max/Min values in the last 24Hrs - updated every 60minutes. Security: Complete lockout or partial lockout(Only setpoint can be changed) + Code protection. Factory default reset

 Icon Electronics 
mAmon,P44 LM(0/1/2) (-T) mAmon,P44 LM(0/1/2) (-T)

P44-LM0/1/2 -: 0 / 4 to 20mA LOOP monitor, 4Digit - 2off 7segment displays, 48 x48 Panelmount. Adjustable window can be set(Hi/Lo) in which relay will energise. Hi and Lo hysterises setpoints. Each fault condition can be disabled. Input is scalable(1500) and decimal point up to 3 places. Each relay can be set with own trip conditions. Adjustable startup delay per relay- Fault monitoring disbabled for this time after power on. (100sec) Adjustable reaction delay per relay- The trip delay time after the fault has occured(100sec). Relay invert status functionality. Can latch one or both relays. Terminal reset. Input signal damping. 4-20mA output for -T models. (0-10V on special request) The 4 -20mA transmitted signal is optically isolated from the input signal The 4 -20mA can be inverted (decreases when input signal increase and vice versa). Onboard 24Vdc /30mA power supply for version -P. Each fault condition is indicated on screen. Records Max/Min values in the last 24Hrs - updated every 60minutes. Security: Complete lockout or partial lockout(Only setpoint can be changed) + Code protection. Factory default reset

 Icon Electronics 
mAmon,P49 LM(0/1/2) (-T) mAmon,P49 LM(0/1/2) (-T)

P49-LM0/1/2 -: 0 / 4 to 20mA LOOP monitor, 4Digit - 1off 7segment display, 96x48 Panelmount. Adjustable window can be set(Hi/Lo) in which relay will energise. Hi and Lo hysterises setpoints. Each fault condition can be disabled. Input is scalable(1500) and decimal point up to 3 places. Each relay can be set with own trip conditions. Adjustable startup delay per relay- Fault monitoring disbabled for this time after power on. (100sec) Adjustable reaction delay per relay- The trip delay time after the fault has occured(100sec). Relay invert status functionality. Can latch one or both relays. Terminal reset. Input signal damping. 4-20mA output for -T models. (0-10V on special request) The 4 -20mA transmitted signal is optically isolated from the input signal The 4 -20mA can be inverted (decreases when input signal increase and vice versa). Onboard 24Vdc /30mA power supply for version -P. Each fault condition is indicated on screen. Records Max/Min values in the last 24Hrs - updated every 60minutes. Security: Complete lockout or partial lockout(only setpoint can be changed) + Code protection. Factory default reset

 Icon Electronics 
mAmon,P49 LM(0/1/2) (-T) mAmon,P49 LM(0/1/2) (-T)

P49-LM0/1/2 -: 0 / 4 to 20mA LOOP monitor, 4Digit - 1off 7segment display, 96x48 Panelmount. Adjustable window can be set(Hi/Lo) in which relay will energise. Hi and Lo hysterises setpoints. Each fault condition can be disabled. Input is scalable(1500) and decimal point up to 3 places. Each relay can be set with own trip conditions. Adjustable startup delay per relay- Fault monitoring disbabled for this time after power on. (100sec) Adjustable reaction delay per relay- The trip delay time after the fault has occured(100sec). Relay invert status functionality. Can latch one or both relays. Terminal reset. Input signal damping. 4-20mA output for -T models. (0-10V on special request) The 4 -20mA transmitted signal is optically isolated from the input signal The 4 -20mA can be inverted (decreases when input signal increase and vice versa). Onboard 24Vdc /30mA power supply for version -P. Each fault condition is indicated on screen. Records Max/Min values in the last 24Hrs - updated every 60minutes. Security: Complete lockout or partial lockout(only setpoint can be changed) + Code protection. Factory default reset

 Icon Electronics 
Meter,D3 SFM(0/1) Meter,D3 SFM(0/1)

D3-SFM0/1 -: AC mains frequency monitor(40 to 65Hz), 4Digit - 2off 7segment displays, DIN mount. Frequency window can be set Hi+hysteris & Lo+hysterises setpoints. Each can be disabled. Adjustable startup delay per relay- Fault monitoring disabled for this time after power on. (100sec) Adjustable reaction delay per relay- The trip delay time after the fault has occured.(100sec) Each fault condition is indicated on screen. Latch facility - terminal reset. Security: Complete lockout or partial lockout + Code protection. Factory default reset.

 Icon Electronics 
Meter,D3 VM1(0/1/2) (-T) Meter,D3 VM1(0/1/2) (-T)

D3-VM0/1/2 - Own supply 300Vac RMS monitor, 4Digit - 2off 7segment displays, DIN mount. EACH relay own high,low and hysterisys setpoints. Input is scalable from 5 to 3500 and decimal point can be set for any position. Front panel calibration +-10% up Startup delay programmable time(100sec). Reaction delay programmable time(100sec). Latch facility Terminals reset Security -Full(Nothing can be changed) or Reduced menu(Setpoint can be changed) lock or open from front panel + code protect Factory default reset

 Icon Electronics 
Meter,D3 VM3(0/1/2) (-N) Meter,D3 VM3(0/1/2) (-N)

D3-VM30/1/2 (N) (-T) - Own supply 500Vac RMS Voltage and Frequency monitor, 4Digit - 2off 7segment displays, DIN mount. Adjustable Each relay - Separate VOLTAGE and FREQUENCY Over/Under trip setpoints with common hysterises,Phase imbalance and trip setpoint + hysterisis adjustment. Each of these fault conditions can be disabled. Phase rotation check(Not disable). *The -N version monitors neutral loss. Input is scalable from 5 to 3500(steps of 5) and decimal point can be set for any position. Front panel calibration +-10% up Each relay can be set with own trip setpoints. Adjustable startup delay- Fault monitoring disbabled for this time after power on.(100sec) Adjustable reaction delay- The trip delay time after the fault has occured.(100sec) Latch + Terminal reset facility 4-20mA output for -T models. (0-10V on special request) Each fault condition is indicated on screen. Security: Complete lockout or partial lockout.+ code protect Factory default reset

 Icon Electronics 
Meter,D3-CMA0/1/2-1 (-T) Meter,D3-CMA0/1/2-1 (-T)

D3-CMA0/1/2-1 (-T): AC current 0-1A (Current transfomers) monitor, 4Digit - 2off 7segment displays, DIN module. Input is scalable from 5 to 5000 and decimal point up to 3 places. Each relay can be set with own trip setpoints. Adjustable Over/Under and common hysterisis trip setpoints,Each of these fault conditions can be disabled. Front panel calibration +-10% up Adjustable startup delay- Fault monitoring disbabled for this time after power on.(100sec) Adjustable reaction delay- The trip delay time after the fault has occured.(100sec) Latch facility 4-20mA output for -T models. (0-10V on special request) Each fault condition is indicated on screen. Security: Complete lockout or partial lockout.+ code protect Factory default reset

 Icon Electronics 
Meter,D3-CMA0/1/2-5 (-T) Meter,D3-CMA0/1/2-5 (-T)

D3-CMA0/1/2-5 (-T): AC current 0-5A (Current transfomers) monitor, 4Digit - 2off 7segment displays, DIN module. Input is scalable from 5 to 5000 and decimal point up to 3 places. Each relay can be set with own trip setpoints. Adjustable Over/Under and common hysterisis trip setpoints,Each of these fault conditions can be disabled. Front panel calibration +-10% up Adjustable startup delay- Fault monitoring disbabled for this time after power on.(100sec) Adjustable reaction delay- The trip delay time after the fault has occured.(100sec) Latch facility 4-20mA output for -T models. (0-10V on special request) Each fault condition is indicated on screen. Security: Complete lockout or partial lockout.+ code protect Factory default reset

 Icon Electronics 
Meter,P44 SFM(0/1) Meter,P44 SFM(0/1)

D3-SFM0/1 -: AC mains frequency monitor(40 to 65Hz), 4Digit - 2off 7segment displays, 48x48mm Panelmount. Frequency window can be set Hi+hysteris & Lo+hysterises setpoints. Each can be disabled. Adjustable startup delay per relay- Fault monitoring disbabled for this time after power on.(100sec) Adjustable reaction delay per relay- The trip delay time after the fault has occured.(100sec) Each fault condition is indicated on screen. Latch facility - terminal reset. Security: Complete lockout or partial lockout + Code protection. Factory default reset.

 Icon Electronics 
Meter,P44 VM1(0/1/2) (-T) Meter,P44 VM1(0/1/2) (-T)

P44-VM0/1/2 - Own supply, 300Vac RMS monitor, 4Digit - 2off 7segment displays, 48x48mm Panel mount. EACH relay own high,low and hysterisys setpoints. Input is scalable from 5 to 3500 and decimal point can be set for any position. Front panel calibration +-10% up Startup delay programmable time(100sec). Reaction delay programmable time(100sec). Latch facility Terminals reset Security -Full(Nothing can be changed) or Reduced menu(Setpoint can be changed) lock or open from front panel + code protect Factory default reset

 Icon Electronics 
Meter,P44 VM3(0/1/2) (-N) (-T) Meter,P44 VM3(0/1/2) (-N) (-T)

P44-VM30/1/2 (N) (-T) - Own supply 500Vac RMS Voltage and Frequency monitor, 4Digit - 1off 7segment display, 48x48mm Panelmount. Adjustable Each relay - Separate VOLTAGE and FREQUENCY Over/Under trip setpoints with common hysterises,Phase imbalance and trip setpoint + hysterisis adjustment. Each of these fault conditions can be disabled. Phase rotation check(Not disable). *The -N version monitors neutral loss. Input is scalable from 5 to 3500(steps of 5) and decimal point can be set for any position. Front panel calibration +-10% up Each relay can be set with own trip setpoints. Adjustable startup delay- Fault monitoring disbabled for this time after power on.(100sec) Adjustable reaction delay- The trip delay time after the fault has occured.(100sec) Latch + Terminal reset facility 4-20mA output for -T models. (0-10V on special request) Each fault condition is indicated on screen. Security: Complete lockout or partial lockout.+ code protect Factory default reset

 Icon Electronics 
Meter,P44-CMA0/1/2-1 (-T) Meter,P44-CMA0/1/2-1 (-T)

P44-CMA0/1/2-1 (-T): AC current 0-1A (Current transfomers) monitor, 4Digit - 1off 7segment display, 48x48mm panelmount. Input is scalable from 5 to 5000 and decimal point up to 3 places. Each relay can be set with own trip setpoints. Adjustable Over/Under and common hysterisis trip setpoints,Each of these fault conditions can be disabled. Front panel calibration +-10% up Adjustable startup delay- Fault monitoring disbabled for this time after power on.(100sec) Adjustable reaction delay- The trip delay time after the fault has occured.(100sec) Latch facility 4-20mA output for -T models. (0-10V on special request) Each fault condition is indicated on screen. Security: Complete lockout or partial lockout.+ code protect Factory default reset

 Icon Electronics 
Meter,P44-CMA0/1/2-5 (-T) Meter,P44-CMA0/1/2-5 (-T)

P44-CMA0/1/2-5 (-T): AC current 0-5A (Current transfomers) monitor, 4Digit - 1off 7segment display, 48x48mm panelmount. Input is scalable from 5 to 5000 and decimal point up to 3 places. Each relay can be set with own trip setpoints. Adjustable Over/Under and common hysterisis trip setpoints,Each of these fault conditions can be disabled. Front panel calibration +-10% up Adjustable startup delay- Fault monitoring disbabled for this time after power on.(100sec) Adjustable reaction delay- The trip delay time after the fault has occured.(100sec) Latch facility 4-20mA output for -T models. (0-10V on special request) Each fault condition is indicated on screen. Security: Complete lockout or partial lockout.+ code protect Factory default reset

 Icon Electronics 
Meter,P49 SFM(0/1) Meter,P49 SFM(0/1)

P49-SFM0/1 -: AC mains frequency monitor(40 to 65Hz), 4Digit - 1off 7segment display, 96x48mm Panelmount. Frequency window can be set Hi+hysteris & Lo+hysterises setpoints. Adjustable startup delay per relay- Fault monitoring disbabled for this time after power on.(100sec) Adjustable reaction delay per relay- The trip delay time after the fault has occured.(100sec) Each fault condition is indicated on screen. Latch facility - terminal reset. Security: Complete lockout or partial lockout + Code protection. Factory default reset.